Skip to Content

BCA610-110-32

https://odoo-preview.cantecsystems.com/web/image/product.template/3133/image_1920?unique=c176729
16.5A, 32V Out, 110VAC In, AC/DC Battery Charger, 2 Bank, CSA/UL
  • Brands
  • Series
  • Industry
  • Volts
  • Amps

This combination does not exist.

Please Log in to see buy options.
The traditional BCA610 series chargers feature 600 watts of precision charging power for 1, 2 or 3 banks of batteries at 12, 24, 32, 36, 48 or 72(rail) volts DC. Models are available to operate from 110 or 220 volts AC at 50, 60 or 400 Hz. All models feature user selectable 2-stage or 3-stage charging profiles, temperature compensation and user initiated equalization for optimum charging and maximum battery life

Features

  • 150 watts of charging power
  • Two or three bank charging
  • Temperature compensation
  • Manual equalization mode
  • Two or three stage charging profiles
  • Low EMI
  • Adjustable float voltage
  • Three year parts and labour warranty
  • Typical Service Life : > 10 years (87,600 hrs)
Volts 32 VDC
Amps 16.5 A
Power-Max 600 W
Efficiency > 90 % at Full Load
Power Factor > 0.98 at Full Load
Frequency-Switching 50 ± 5% kHz
Voltage-In 90 - 130 VAC
Frequency-In 45 - 65 Hz
Current-In 3 A with Inrush Protection
Phase Single Phase
Banks 2
Stages 2 or 3 stage user selectable
Temp-Operating -25°C to +40°C @ maximum output. Derate Linearly 2.5% per °C from 40°C
Humidity 0 - 95% Relative Humidity (non-condensing) with standard conformal coating
Isolation In-Out > 1500 VDC
Isolation In-Case > 1500 VDC
Isolation Out-Case > 1500 VDC
Fuse-Out AGC-25
Length 36.8  cm
Width 25.1  cm
Height 14.0  cm
  • Material and Finish : Marine Grade Black Anodized Aluminum with 18-8 Stainless Fasteners
  • Wall Mount (With Drip Shield)
  • Connections : AC Input - IEC Inlet 26.4mm Tab Flange Mount, DC Output - Phoenix VDFK 4 Connector (Black and Red)
  • Military
  • Industrial
  • Telecommunications
  • Transportation
  • Alternative Energy
  • Emissions Meets FCC Part 14, Class B
  • Warranty : Three Years Parts and Labor
  • Safety Built to meet CSA C22.2 No.107.1 and UL 458