Skip to Content

BCA310-110-48

https://odoo-preview.cantecsystems.com/web/image/product.template/3129/image_1920?unique=c176729
5.0A, 48V Out, 110VAC In, AC/DC Battery Charger, 3 Bank
  • Brands
  • Series
  • Industry
  • Volts
  • Amps

This combination does not exist.

Please Log in to see buy options.
The traditional BCA310 series chargers feature 300 watts of precision charging power for 1, 2 or 3 banks of batteries at 12, 24, 32, 36, 48 or 72(rail) volts DC. Models are available to operate from 110 or 220 volts AC at 50, 60 or 400 Hz. All models feature user selectable 2-stage or 3-stage charging profiles, temperature compensation and user initiated equalization for optimum charging and maximum battery life

Features

  • 150 watts of charging power
  • Two or three bank charging
  • Temperature compensation
  • Manual equalization mode
  • Two or three stage charging profiles
  • Low EMI
  • Adjustable float voltage
  • Three year parts and labour warranty
  • Typical Service Life : > 10 years (87,600 hrs)
Volts 48 VDC
Amps 5 A
Power-Max 300 W
Efficiency > 90 % at Full Load
Power Factor > 0.98 at Full Load
Frequency-Switching 50 ± 5% kHz
Voltage-In 85 - 265 VAC
Frequency-In 45 - 65 Hz
Current-In 3 A with Inrush Protection
Phase Single Phase
Banks 3
Stages 2 or 3 stage user selectable
Temp-Operating -25°C to +40°C @ maximum output. Derate Linearly 2.5% per °C from 40°C
Humidity 0 - 95% Relative Humidity (non-condensing) with standard conformal coating
Isolation In-Out > 1500 VDC
Isolation In-Case > 1500 VDC
Isolation Out-Case > 1500 VDC
Fuse-Out AGC-7
Length 24.4  cm
Width 20.8  cm
Height 8.8  cm
  • Material and Finish : Marine Grade Black Anodized Aluminum with 18-8 Stainless Fasteners
  • Wall Mount (With Drip Shield)
  • Connections : AC Input - IEC Inlet 26.4mm Tab Flange Mount, DC Output - Phoenix VDFK 4 Connector (Black and Red)
  • Military
  • Industrial
  • Telecommunications
  • Transportation
  • Alternative Energy
  • Emissions Meets FCC Part 14, Class B
  • Warranty : Three Years Parts and Labor
  • Safety Built to meet CSA C22.2 No.107.1 and UL 458
BCA310 Datasheet
Download
BCA310 Manual
Download



 Contact Us

1-866-381-1595
Ottawa 613-725-3704
info@cantecsystems.com


Visit Us 

17 Enterprise Avenue, Unit G

Ottawa ON K2G 0A7

Canada 


We accept all major card